BSUSat-1

KB6LTY at 2019-09-12T16:10:14.320Z Screenshot

RF Beacon Parameters Value
Modem ID 1
Operation time after last reset 95 sec
Modem reboot counter 254
AT90CAN128 MCUSR register 5
Tx power amplifier temperature 35.4 °C
Tx power amplifier voltage 2.2 V
Tx power attenuation 1.5 dB
Battery voltage 8.25 V
System voltage 4.98
Rx sequence number 1
Power save state on
Modem rx state period 10 sec
Last CAN communication status with OBC UNKNOWN
Last CAN communication status with EPS OK
Size of info in the packet 64 bytes
Type of data 254
EPS data Value
EPS system time 6410 sec
ADC Correctness 0
ADC 1 Temperature 29.375 °C
ADC 2 Temperature 29.375 °C
Current after StepUp 252.787 mA
StepUp Voltage 9.329 V
Current after BQ 93.018 mA
Battery Voltage 8.253 V
5V System voltage 5.151 V
3.3V System voltage 3.314 V
Current to EPS 23.112 mA
Current to OBC 58.268 mA
Current to Modem 1 0 mA
Current to Modem 2 80.566 mA
Solar Panels voltage 4.684 V
Current from Solar X 414.063 mA
Current from Solar pY 72.754 mA
Current from Solar nY 3.174 mA
Current from Solar pZ 0 mA
Current from Solar nZ 1.709 mA
Current to Gamma sensor 2.197 mA
Current to IR sensor 0.814 mA
Current to External Flash 0.285 mA
Current to Sun Sensors 1.526 mA
Current to Coils Control system 0.732 mA
Current to coil X 1.831 mA
Current to coil Y 0.203 mA
Current to coil pZ 2.832 mA
Current to coil nZ 0.781 mA
Battery 1 temperature 27.951 °C
Battery 2 temperature 28.179 °C
OBC overcurrent counter 4
Gamma overcurrent counter 0
Modem 1 overcurrent counter 0
Modem 2 overcurrent counter
External Flash overcurrent counter 0
IR sensor overcurrent counter 0
Coil X overcurrent counter 0
Coil Y overcurrent counter 0
Coil pZ overcurrent counter 0
Coil nZ overcurrent counter 0
Coils Control system overcurrent counter 0
Sun Sensor overcurrent counter 0
EPS reboot counter 15
EPS reset reason 4
System power switch state 1
Modem 1 power switch state 0
Modem 2 power switch state 1
Sun Sensors power switch state 0
Gamma Sensor power switch state 0
IR Sensor power switch state 0
External Flash power switch state 0
X Axis control system power switch state 0
Y Axis control system power switch state 0