BSUSat-1

JA6PL at 2021-03-01T23:02:18.170Z Screenshot

RF Beacon Parameters Value
Modem ID 1
Operation time after last reset 55 sec
Modem reboot counter 238
AT90CAN128 MCUSR register 5
Tx power amplifier temperature 47.89 °C
Tx power amplifier voltage 2.2 V
Tx power attenuation 1.5 dB
Battery voltage 8.18 V
System voltage 4.98
Rx sequence number 1
Power save state on
Modem rx state period 10 sec
Last CAN communication status with OBC UNKNOWN
Last CAN communication status with EPS OK
Size of info in the packet 64 bytes
Type of data 254
EPS data Value
EPS system time 54724 sec
ADC Correctness 0
ADC 1 Temperature 39.75 °C
ADC 2 Temperature 40.375 °C
Current after StepUp 2.136 mA
StepUp Voltage 9.304 V
Current after BQ 150.391 mA
Battery Voltage 8.192 V
5V System voltage 5.15 V
3.3V System voltage 3.315 V
Current to EPS 23.153 mA
Current to OBC 58.105 mA
Current to Modem 1 0 mA
Current to Modem 2 98.572 mA
Solar Panels voltage 4.817 V
Current from Solar X 16.602 mA
Current from Solar pY 2.441 mA
Current from Solar nY 0.732 mA
Current from Solar pZ 0 mA
Current from Solar nZ 2.441 mA
Current to Gamma sensor 2.197 mA
Current to IR sensor 0.773 mA
Current to External Flash 0.285 mA
Current to Sun Sensors 1.587 mA
Current to Coils Control system 0.732 mA
Current to coil X 1.831 mA
Current to coil Y 0.203 mA
Current to coil pZ 2.881 mA
Current to coil nZ 0.757 mA
Battery 1 temperature 39.029 °C
Battery 2 temperature 39.213 °C
OBC overcurrent counter 10
Gamma overcurrent counter 0
Modem 1 overcurrent counter 0
Modem 2 overcurrent counter
External Flash overcurrent counter 0
IR sensor overcurrent counter 0
Coil X overcurrent counter 0
Coil Y overcurrent counter 0
Coil pZ overcurrent counter 0
Coil nZ overcurrent counter 0
Coils Control system overcurrent counter 0
Sun Sensor overcurrent counter 0
EPS reboot counter 26
EPS reset reason 4
System power switch state 1
Modem 1 power switch state 0
Modem 2 power switch state 1
Sun Sensors power switch state 0
Gamma Sensor power switch state 0
IR Sensor power switch state 0
External Flash power switch state 0
X Axis control system power switch state 0
Y Axis control system power switch state 0
Z Axis control system power switch state 0